Search results for "energy-resolved photon-counting detectors"

showing 2 items of 2 documents

Development of new CdZnTe detectors for room-temperature high-flux radiation measurements

2017

Recently, CdZnTe (CZT) detectors have been widely proposed and developed for room-temperature X-ray spectroscopy even at high fluxes, and great efforts have been made on both the device and the crystal growth technologies. In this work, the performance of new travelling-heater-method (THM)-grown CZT detectors, recently developed at IMEM-CNR Parma, Italy, is presented. Thick planar detectors (3 mm thick) with gold electroless contacts were realised, with a planar cathode covering the detector surface (4.1 mm × 4.1 mm) and a central anode (2 mm × 2 mm) surrounded by a guard-ring electrode. The detectors, characterized by low leakage currents at room temperature (4.7 nA cm−2 at 1000 V cm−1), a…

Nuclear and High Energy PhysicsPreamplifier02 engineering and technologydigital pulse shape analysiRadiation01 natural scienceslaw.inventionPlanarOpticstravelling heater methodlaw0103 physical scienceshigh fluxInstrumentationenergy-resolved photon-counting detectorsNuclear and High Energy PhysicPhysicsRadiationdigital pulse shape analysis010308 nuclear & particles physicsbusiness.industryCdZnTe detectorsCdZnTe detectorDetectorSettore FIS/01 - Fisica SperimentaleX-ray and γ-ray detectorenergy-resolved photon-counting detector021001 nanoscience & nanotechnologyCathodeSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Anodegold electroless contactFull width at half maximumX-ray and -ray detectors0210 nano-technologybusinessVoltage
researchProduct

Dual-polarity pulse processing and analysis for charge-loss correction in cadmium–zinc–telluride pixel detectors

2018

Charge losses at the inter-pixel gap are typical drawbacks in cadmium–zinc–telluride (CZT) pixel detectors. In this work, an original technique able to correct charge losses occurring after the application of charge-sharing addition (CSA) is presented. The method, exploiting the strong relation between the energy after CSA and the beam position at the inter-pixel gap, allows the recovery of charge losses and improvements in energy resolution. Sub-millimetre CZT pixel detectors were investigated with both uncollimated radiation sources and collimated synchrotron X-rays, at energies below and above the K-shell absorption energy of the CZT material. The detectors are DC coupled to fast and low…

0301 basic medicine030103 biophysicsNuclear and High Energy PhysicsMaterials sciencePreamplifierPhysics::Instrumentation and Detectors01 natural sciencesCollimated lightCharge sharinglaw.invention03 medical and health scienceschemistry.chemical_compoundOpticslawcharge losse0103 physical sciencesInstrumentationenergy-resolved photon-counting detectorsNuclear and High Energy Physiccharge lossescharge sharingRadiationPixel010308 nuclear & particles physicsbusiness.industryCdZnTe detectorsCdZnTe detectorDetectorSettore FIS/01 - Fisica Sperimentaleenergy-resolved photon-counting detectorSynchrotronSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Cadmium zinc tellurideX-ray and gamma-ray detectorschemistryDirect couplingbusinessX-ray and gamma-ray detector
researchProduct